Skip links

数据中心

BGP

全球数据

中心的优势

BGP所处的数据中心在全国市场上服务超过75家前500大的公司,这可以帮助解决您在全球业务上的需求。

全球品质保证数据中心

BGP Data Centers are uniquely situated in the heart of technology centers around the world. Our bi-coastal presence not only offers geographic redundancy for ideal latency optimization but are also home to the largest fiber cable landings on the western and eastern seaboards that connect to Asia and US. Our data centers are all carrier neutral, each with top tier providers and exchange points.

网路服务覆盖范围

新加坡

9层钢筋混凝土结构产品 更多资迅

Tokyo (Japan)

9层钢筋混凝土结构产品 更多资迅

Taipei (Taiwan)

9层钢筋混凝土结构产品 更多资迅

Seoul (South Korea)

9层钢筋混凝土结构产品 更多资迅

Hongkong

9层钢筋混凝土结构产品 更多资迅

San Jose (United States)

9层钢筋混凝土结构产品 更多资迅

Los Angeles (United States)

9层钢筋混凝土结构产品 更多资迅

Bangkok (Thailand)

9层钢筋混凝土结构产品
更多资迅

Ho Chi Minh (Vietnam)

9层钢筋混凝土结构产品
更多资迅

为您的服务找一个新家!

EQUINIX SG 1

数据中心建筑资讯: 9层加强型结构建筑提供109,209平方英尺的分散式管理空间。

关于数据中心: Equinix 的IBX SG1数据中心地址在20 Ayer Rajah Crescent,地理位置优越位于One-North的中心位置,邻近Technopolis。One-North的开发是在新加坡重点开发专案Technopreneur 21下新加坡成功发展的高科技企业区域。

不中断电源供应系统发电机: 提供备用电源冗于N+1让设备有最大化的运行时间。基础设施包含不中断电源供应系统避免电源尖峰,突波与停电,由冗于备用柴油发电机提供额外的电力运行。使用中所有自动运行的电力系统,IBX 工程团队可以监控所有电力系统在数据中心或者远端,以快速回覆各种解决方案。

安全性: 全部的门,包含笼子,皆安装手部识别鉴装置,动力钥匙锁关闭机柜,与闭路电视数位镜头监视范围覆盖整个数据中心,包含笼子。

紧急保护措施: 完整的可定位的火灾检测系统在所有区域,预先警示烟雾检测系统(监控 24x7x365)。干式预测洒水系统与内部煤气抑制系统在技术区域。

GLOBAL SWITCH

数据中心建筑资讯: 占地26,743平方公尺 & 7层数据楼层

关于数据中心: 可扩充的IT空间,宗旨在建立超越Tier 3 运作性能。

不中断电源供应系统: 电源供应容量 25MVA(目前使用与已计画)。技术使用电源供应在机房主要建置 2​​N的静态不中断电源供应系统与柴油旋转式不中断电源供应系冗于备援N+1延展。

发电机: 22kV 效能供应有冗于备援N+N。机械系统供电来自于主要建置的柴油备源发电系统有N+1冗于备援。

安全性: 运作中心与安管人员巡视24x7x365。建置连续的闭路电视监视外部与内部区域。闭路电视储存资料持续31天,有全方位的入侵诊断与警告系统在全部的区域。

紧急保护措施: 完整的可定位的火灾检测系统在所有区域,预先警示烟雾检测系统(监控 24x7x365)。干式预测洒水系统与内部煤气抑制系统在技术区域。

TOKYO - EQUINIX TY2

数据中心建筑资讯: 占地58,992 平方英尺

关于数据中心: Equinix TY2品川区数据中心位于日本东京都品川区东品川。总共有22,301平方英尺高架地板的空间给主机管理。接取电源6.75 MW。

不中断电源供应系统发电机: 提供备用电源冗于N+2让设备有最大化的运行时间。基础设施包含不中断电源供应系统避免电源尖峰,突波与停电,由冗于备用柴油发电机提供额外的电力运行。使用中所有自动运行的电力系统,IBX 工程团队可以监控所有电力系统在数据中心,或者远端,以快速回覆各种解决方案。

安全性: 全部的门,包含笼子,皆安装手部识别鉴装置,动力钥匙锁关闭机柜,与闭路电视数位镜头监视范围覆盖整个数据中心,包含笼子。

紧急保护措施: 完整的可定位的火灾检测系统在所有区域,预先警示烟雾检测系统(监控 24x7x365)。干式预测洒水系统与内部煤气抑制系统在技术区域。

TOKYO - COLT TDC1

关于数据中心: Colt东京盐滨数据中心位于日本江东区是专门为服务金融行业的紧急需求而建立。

不中断电源供应系统发电机: 提供完整2(N+1)冗于电源备有双回路透过完备的分离基础设施到达机柜。

安全性: 操作与安全性程序都遵循公开的国际基本规则,包含ISMS/ISO27001,SSAE16 Type II certifications B56 和 FISC方针。

紧急保护措施: 数据中心备有内部气体火灾抑制系统结合消防栓与灭火器设置在所有的区域配合VESDA预先警示系统,高灵敏度烟雾探测器,24/7现场待命的安全管理人员与多层物理安全性管理与生物验证系统。

TAIPEI - CHIEF TELECOM

数据中心建筑资讯: 完全分离之电力,电信线槽。高品质汇流铜排 (class F) 设计。接地电阻 < < 0.5 Ω。

关于数据中心: Tier 3数据中心,每回路20A插入式开关,升级不中断。

不中断电源供应系统: 北有双回路且才采N+1备援。

发电机: 每台1500KW的发电机,N+1备援24小时持续运作的发电机系统,双循环与N+1不中断电源供应系统(600KVA),柴油发电机备援。

安全性: 24小时警卫巡逻与车道管制,指纹辨识与磁卡感应系统,360度监视器与自动侦测系统监控,有多层安全性考量。

紧急保护措施: 环境监控系统,包含VESDA早期侦烟告警系统,FM-200消防系统,多层诊断避免错误警示,二氧化碳与粉末灭火器是紧急状态的运作流程。

SEOUL - KINX

关于数据中心: 数据中心运行使用 L2-based IX (Internet eXchange)。 KINX数据中心提供服务直接与重要的海内外电信商连接。完整的设备有优化的网路环境以及建设,基础设施,电源.冷却与加热系统与安全性设备。

UPS Systems & Generator : 数据中心备有电源变电站–超大型高压系统以提供安全优质的电源品质。不中断电源系统N+1备援,稳定的电源供应与30分钟电源备援时间设计(满载)。紧急电源供应系统–停点时在8~12秒之内恢复电源供应,确保燃料足够紧急的运作超过12小时。

安全性: 提供24/7监控&住所,严谨的验证管理透过个人ID与指纹辨识验证系统,快速回应各种障碍包含NMS & What’s Up 系统与中心连接控制,协助成员的作业,成员的流量分析数据。

紧急保护措施: 数据中心维持最佳的温度与湿度(23± 2 ℃, 30 ~ 60%)。自动化的告警来自泄漏感测线路。最佳化 HAVC系统来自安装更高的高架地板:电源线槽在高架地板之下,通信线槽在高架地板之上。冷却系统通过温度调节与混合水气在空气之中。自动化火警侦测系统与紧急警示系统。

IADVANTAGE MEGA-I

数据中心建筑资讯: 这座楼高30层、建筑面积达350,000平方呎的数据中心具备顶级的基建设施和具真正延展性的环球性网络,可针对客户各种电力和设施规格需要提供度身订制的专业服务。

关于数据中心: MEGA-i 是全球最大型的数据中心之一可提供灵活的数据中心服务,包括开放式机柜大堂以至按客户要求搭建的专属房间,供客户选择。我们的客户来自不同行业,包括中小型企业、跨国企业、环球电讯商、互联网服务和云端服务供应商等。

不间断电源与发电机系统: N+1 / 2N UPS 配置,15 分钟的电池量与双电缆 /UPS 电源至机柜。

安全性: 24 小时闭路电视监控附数码录影功能与24 小时保安人员实施出入管制。

紧急保护措施: FM-200 气体 / Novec 1230 气体 / Inergen 气体灭火系统与防火复合自动洒水系统。

IADVANTAGE MEGA TWO

Building : 现有大厦改建为资讯科技及电讯业用途的数据中心楼面面积约 520,000 平方呎。

关于数据中心: Mega-I 2提供最高层级的数据中心解决方案给不同规模的客户包括内地的网络营运商、金融机构、云端服务商、IT服务供应商、系统整合商以及业务覆盖全球及内地的跨国企业。

不中断电力系统: N+1 / 2N UPS 配置,15 分钟的电池量,提供双电源回路220 V / 单相,50 Hz电压至机柜。多油缸设计总容量:85,000 公升提供给备用柴油机运作。

安全性: 精密门禁系统与防冲门和24 小时闭路电视监控附数码录影功能。任何时间的保安人员实施出入管制。

紧急保护措施: FM-200 气体 / Novec 1230 气体 / Inergen 气体灭火系统与防火复合自动洒水系统与漏水警报距离定位系统。

SAN JOSE - EQUINIX SV5

数据中心建筑资讯:  126,569 square feet of total space, including 63,948 square feet of colocation space, and flex space of 2,134 square feet. The floor load is designed for colocation area of 175 lbs. per square feet, electrical area of 250 lbs. per square feet, and office area of 100 lbs. per square feet.

关于数据中心:  This data center is a carrier neutral facility offering connectivity to multiple carriers and service providers. It has overhead proprietary cable tray system with multi-tier ladder rack.

不中断电源供应系统: The facility has 21.6 kV of utility voltage. The immediate power failure is protected by UPS system in 5+1 blocked redundant topology for a total of 5 primary buses, and 1 redundant bus.

发电机:  The standby power is provided by 6 x 3,000 kW diesel generators in N+1 configuration.

安全性:  The data center has multilevel security including CCTV & recorders, motion detection, and 24 x 7 security guards. All doors, including cages, are secured with biometric hand geometry readers, and closed cabinets with kinetic & key locks.

紧急保护措施: Fully addressable fire detection system in all areas, aspirated early warning smoke detection system (monitored 24x7x365). double interlocked, dry pipe sprinkler system is installed in the data center for life safety.

LOS ANGELES - ONE WILSHERE

数据中心建筑资讯:  149,000+ square feet of data center space.

关于数据中心:  Located in the downtown area, One Wilshere is one of the industry’s premier points of interconnection and the most recognizable LA data center. It is one of the most significant points of connectivity in Western United States as well as throughout the world.

不中断电源供应系统发电机: The data center power failure is protected by N, N+1, and 2N configured Mitsubishi, Powerware and Eaton high-efficiency UPS systems and automatic transfer to diesel generator with N, N+1, 2N redundancy.

安全性:  The facility is SSAE 16 Type II certified and provides the excellent security features through onsite officers, mantraps, and CCTV surveillance. The key card and biometric scanners are installed at multiple checkpoints guarding access to resources in the data center.

紧急保护措施: The data centers cooling and humidity is maintained through N+1 chillers, cooling towers, CRAHs, and chilled water pumps. The double interlock pre-action sprinkler system with VESDA fire suppression system is installed in the data center for life safety.

BANGKOK - CAT-IDC

Building Information : 14 storey building with 1,000 square metre with 2 sets of generator (2 x (3 x 1,900 kVa)).

DC description : With 6 service providers, CAT Telecom’s CAT-IDC is ranked #1 in the Bangkok market. At a national level it is ranked #2 out of 25 co-location facilities.

不中断电力系统: Powered by 2 x 400 kVa system with external bypass system it is able to handle full load backup up to 15 minutes.

安全性: Bullet proof glass checkpoint with 24/7 security officer presence and 5 factor authentication to prevent unauthorised access to the facility. Biometric fingerprint ready and CCTV (retention up to 90 days) surveillance for added measures.

Emergency protection : Very Early Warning Fire Detection and Water Mist Protection System (Marioff HI-FOG).

HO CHI MINH - FPT-IDC

Building Information : 3,300 square metre with a floor loading of 1,000kg square metre and ceiling heights of 3.2 metre.

DC description : With 6 service providers, CAT Telecom’s CAT-IDC is ranked #1 in the Bangkok market. At a national level it is ranked #2 out of 25 co-location facilities.

不中断电力系统: Powered by 2 x 1250 kVa capacity to prevent surge or brown out. The feed is supported by local utility power supply. Generator capacity 3 x 1250 kVa + 2 x 2500 kVa with fuel capacity of 10,000 litres (last up to 48 hours) for all critical systems.

安全性: Professional security personnel on duty 24x7x365 with automatic barrier and entry access control. Biometric fingerprint readers on door locks, strategically placed cameras, motion detection and alarm system.

Emergency protection : FM200 gas suppression system with double interlock pre-action sprinkler system and VESDA system.

保护您的服务器免受 DDos 攻击